Section drawings, report relationships and unresolved geometry
Check catalogue section identity, held drawing candidates and the exact information still required before order or evidence release.
What has been checked
284 source-coded profile section references have independent catalogue pages. They record historical geometry, not confirmed active stock, controlled order drawings or verified load ratings. Existing matched sample-report relationships remain unchanged; no new profile section inherits another model’s report.
Six drawing candidates — no approved replacement sequence
I6015: three A0 files record 6000 × 1000, 6100 × 1000 and 830 × 591 mm geometries. T5020: one A0 covering/fabrication drawing. 50X50S50: two A0 panel drawings record 3007 × 1007 and 1007 × 1007 mm. These are identity-confirmed candidates, not released order drawings. Current BOM/resin/surface, approval dates, specimen-to-drawing traceability and external-release status remain unresolved.
Model–report limits
I6015: the existing 2014 E84 sample report does not identify which A0 panel drawing it covers. T5020: the covering assembly is not established as the bare E84 specimen; resolve the historical manual’s 51 mm versus report nominal 50 mm. 50X50S50: neither panel drawing identifies the 1230 × 450 × 50 mm / CO350 tested component. No blanket capacity, fire class or current certification is inferred.
Printed p.47: C41.3
Printed thickness reads 38 × 38 in a 41.3 × 41.3 channel row; do not silently correct to 3.8.
Printed p.49: STR25
The row is adjacent to a handrail U-shape sketch; square versus shaped section identity requires a controlled drawing.
Printed p.50: EL30A / L70 special
75-degree / special-section geometry requires its own dimensioned drawing before treating the tuple as an ordinary angle.
Printed p.51: IB45A
Printed 45 × 9.0 × 180 × 12.0 sequence does not safely identify A/B/t1/t2.
Printed p.52: Flat-strip FS100 (chamfered edge)
Duplicate FS100 labels appear with differing dimensions; unique current part identity missing.
Printed p.50: Deck (3 unnumbered sections)
No unique catalogue model codes or current controlled drawing; do not invent product model numbers.
Printed p.53: Y / T sections (10 unnumbered rows)
Dimension tuples are printed but no unique model codes; current drawing identifiers are missing.
Printed p.55: Hook plates (3 unnumbered rows), open-web plate
No unique model codes; open-web weight printed 8040 has ambiguous units. Do not invent codes or silently normalise weight.
Printed p.54: FS102A
Printed 102 × 32 may omit a decimal; retain in original, do not silently correct to 102 × 3.2 or publish a manufacturing size.
Printed p.52: FS50A / FS60A / FS100 chamfered-strip rows
Repeated or colliding identifiers and edge treatments differ from flat-lath entries. An approved unique part number and shape drawing are required; no automatic code equivalence.
Review technical evidence · Send your project conditions
Relevant product families
Pultruded FRP tubesPultruded FRP tubes for frame, rail and OEM component selection. Compare section shapes and dimensions, then send your drawing, cut lengths and quantities for supply review.
FRP rods & flat barsFRP solid rods and flat bars for fabricated components. Find a catalogue section, check its dimensions, then send your cut lengths, tolerances and quantities for quotation review.
FRP beams & structural profilesFRP beams, channels and angles for fabricated structures. Compare catalogue sections, then send your drawing, connections and design conditions to define the supply and evidence you need.
I6015 pultruded gratingI6015 pultruded FRP grating for walkways and equipment access. Compare the recorded geometry and sample-report scope, then send your span, load conditions and cut sizes for quotation review.
T5020 pultruded gratingT5020 pultruded FRP grating for walkway and platform selection. Check the catalogue geometry and separate report scope, then send your support layout, cut sizes and required surface for review.
50 × 50 × 50 mm moulded grating50 mm-deep moulded FRP grating with 50 × 50 mm mesh for platform selection. Review the sample load conditions, then send your span, loads and panel sizes for configuration review.