MACHS

Pultruded grating

T5020 pultruded grating

T5020 pultruded FRP grating for walkway and platform selection. Check the catalogue geometry and separate report scope, then send your support layout, cut sizes and required surface for review.

MACHS supplied pultruded grating representative product-family photograph
Representative pultruded grating photograph from the MACHS supplied archive. Confirm the exact geometry, dimensions, resin and surface against the approved order drawing; the photograph is not evidence of the tested configuration.
← Pultruded grating

Specification notes

ModelT5020
Depth50 mm (report sample)

Parameter source: P02 → report 003 / V9 2026-11-05 / V8 R3. Only the listed configuration is described. Missing dimensions, mass and working loads are not estimated.

Start with the load path

Confirm the bearing-bar layout, support positions and panel direction on a drawing. The recorded 50 mm sample depth does not establish the bearing-bar spacing, panel size or allowable working load for your installation.

Read the report before naming a fire class

The linked ASTM E84 sample report identifies its own tested conditions and results. Use that complete original when reviewing a project requirement; the presence of a fire test is not a blanket fire classification for the full product family.

Define the order

Provide the resin and surface requirement, panel or finished-part size, quantity, cutouts, fixings and destination. If dimensions or performance requirements are still open, identify them explicitly for technical review.

How to specify this grating

Start with a plan showing the supporting members and the bearing bars. Pultruded bearing bars carry the principal load in their longitudinal direction; panel orientation and cut-outs must therefore be reviewed with the supports. A matching depth or model name alone does not establish interchangeable performance.

Application and supply scope

This configuration can be considered during the selection of industrial walkways, access platforms or equipment access areas. These are selection scenarios, not a claim that every installation is approved. Confirm personnel or equipment loads, wet or contaminated conditions, chemical exposure, temperature, fire requirements and the governing project specification.

Catalogue dimensions versus an approved order

The table below transcribes the supplied English catalogue, PDF 18 / printed 33; PDF 23 / printed 43. It is a catalogue reference, not an approved order drawing or confirmation of current stock. Existing V9 and original-report sample identities remain unchanged. Values not confirmed by an approved drawing must be reviewed before ordering; catalogue weight discrepancies are retained rather than silently corrected.

Surface, cutting and installation decisions

Specify the walking surface separately from the bearing-bar geometry: smooth, gritted, grooved or covered configurations require their own confirmation. State the panel outline, cut-outs, edge treatment, fixing positions, support contact and whether supply is full panels or cut parts. Neither a surface photograph nor the word anti-slip establishes a particular slip rating.

What a useful quotation should include

Provide the model or referenced section, drawing number and revision, panel or cut-part quantities, finished sizes and units, required resin and surface, support layout, loads and deflection criteria, destination and required documents. Mark undecided items for review. Confirm whether clips, fabrication, inspection records and packing are included so quotations cover the same scope.

Swipe or scroll the table horizontally to read all columns on a small screen.

Supplied catalogue reference — order review required
ItemCatalogue entryUse condition
Catalogue designationT-5020Do not merge a similar profile/report code automatically
Depth (mm)50Catalogue geometry; report sample identity remains separately stated
Top width (mm)25.4Confirm actual bearing-bar section
Bearing-bar pitch (mm)50.8Pitch is not the same as clear opening
Clear gap (mm)25.4Confirm against section drawing
Open area (%)50Does not establish load capacity or slip rating
Catalogue mass (kg/m²)17.2 in summary; 15.66 on detail page — unresolvedReference only; confirm configuration and revision
SourcePDF 18 / printed 33; PDF 23 / printed 432023 Machs English version Catalog.pdf; filename is not an approved revision date
Can I use the catalogue maximum load as the working load?

No. A maximum or ultimate load is not an allowable working load. Match the exact section and support condition, distinguish line and distributed loading, and agree the design method, load factors and deflection limit with the project engineer. Unverified catalogue load values are not a project design release.

Does the linked fire report cover every resin and surface?

No. Check the named specimen, formulation, thickness, surface and test method in the complete original. A similarly named profile, customer reissue or different resin does not automatically extend the tested scope.

Technical pack for this configuration

Use the model, drawing revision and tested conditions together. Missing files are not evidence of a verified specification.

260811011SHF-002

T5020;拉挤格栅;约50mm厚

T5020, approximately 50 mm sample. FSI 40 / SDI 1000; does not support a Class A claim. Only the identified tested specimen/configuration. Matching nominal dimensions does not establish the same resin, formulation, surface, batch or working load. Confirm the proposed supply against the complete original report.

Applicant / publisher: Nantong Machs Composite Material Co., Ltd. (as recorded in original) · Source: MACHS original sample report

Version: As issued; see original · Sample report; not a product certification

Reference / method: ASTM E84-26a · Issued: 2026-08-26

No blanket current certification or working-load claim. A report without an expiry date is still sample-specific.

Read document scope and preview Download original (PDF)

English product catalogue

Product families and catalogue configurations

Historical catalogue reference; not a test report, certification, current stock statement or approved order drawing. Catalogue mass and load-table discrepancies require review.

Applicant / publisher: Publisher identified in the catalogue: MACHS · Source: Document reference

Version: Filename includes 2023; approved issue/revision date not verified · Catalogue reference — order applicability review required

Reference / method: Product reference · Issued: See original

Use current website contact details and V9 company facts. Catalogue material, load and fire claims do not replace matched original reports or project engineering.

Read document scope and preview Download original (PDF)

Drawing candidate: identity confirmed; order and report applicability NOT confirmed.

T5020%20covering · b69ae766

Covering/fabrication drawing; not the bare E84 specimen

Confirmed: the drawing title, printed A0 revision and the dimensions stated above. Not confirmed: current ordered configuration or correspondence to the tested specimen. Covered/fabricated assembly is not established as the bare T5020 E84 specimen. Missing controlled section/BOM, resin/surface traceability, current model mapping and external release. Reconcile manual depth 51 mm with the report nominal 50 mm; this covering drawing is not evidence that the complete assembly was fire-tested.

Applicant / publisher: Nantong Machs Composite Material Co., Ltd. (as printed) · Source: Document reference

Version: A0 (printed; no approved issue date recorded) · Parallel candidate — not an approved successor

Reference / method: Drawing reference — not a test report · Issued: See original

Covered/fabricated assembly is not established as the bare T5020 E84 specimen. Missing controlled section/BOM, resin/surface traceability, current model mapping and external release. Reconcile manual depth 51 mm with the report nominal 50 mm; this covering drawing is not evidence that the complete assembly was fire-tested.

Original is held for release / applicability review.

Installation planning checklistRequest missing or applicable files

Compare this configuration

Installation planning · Your buying path · Technical resources

Applications

Coordinate grating, framing, rails and connections.Plan industrial platforms and equipment accessCoordinate the component list, support and connection details, maintenance openings and responsibility for installation.

Technical resources

Section drawings, report relationships and unresolved geometryCheck catalogue section identity, held drawing candidates and the exact information still required before order or evidence release.

Selection guides

MACHS pultruded FRP grating panels in the workshop; representative family photograph, not a tested specimen identificationChoose moulded or pultruded gratingUse the support layout and load path to choose a starting configuration, then check the exact panel and its evidence.MACHS pultruded FRP grating panels in the workshop; representative family photograph, not a tested specimen identificationChoose resin from the actual exposureSend chemical concentration, temperature and contact conditions before asking which resin is suitable.MACHS pultruded FRP grating panels in the workshop; representative family photograph, not a tested specimen identificationCompare grating quotations on the same basisAlign the configuration, finished quantities and delivery scope before comparing the total price.MACHS pultruded FRP grating panels in the workshop; representative family photograph, not a tested specimen identificationRead a load table with its support conditionsMatch the panel, support arrangement, span and loading before using a load value.MACHS pultruded FRP grating panels in the workshop; representative family photograph, not a tested specimen identificationFRP grating selection: span, load and support checklistDefine supports, loads and drawing conditions before asking whether I6015 or T5020 is suitable.MACHS pultruded FRP grating panels in the workshop; representative family photograph, not a tested specimen identificationI6015 vs T5020: geometry, report scope and selection questionsCompare recorded geometry and original fire-report specimens while keeping unresolved drawing and version gaps visible.

Related products in this family

Review the section, dimensions and evidence for each entry. A related product is not an interchangeable or approved substitute.

MACHS supplied pultruded grating representative product-family photographHL-6020 pultruded gratingHL-6020 pultruded FRP grating for industrial walkway selection. Compare the catalogue geometry and bearing direction, then send your span, loads and cut sizes for technical and quotation review.MACHS supplied pultruded grating representative product-family photographHL-5020 pultruded gratingHL-5020 pultruded FRP grating for industrial walkway selection. Compare the catalogue geometry and bearing direction, then send your span, loads and cut sizes for technical and quotation review.MACHS supplied pultruded grating representative product-family photographHL-4020 pultruded gratingHL-4020 pultruded FRP grating for industrial walkway selection. Compare the catalogue geometry and bearing direction, then send your span, loads and cut sizes for technical and quotation review.

Request specifications

Selected product: T5020 pultruded grating. This configuration is included with your enquiry.

State known conditions and write "not sure — please advise" for anything unresolved. No need to guess the resin or load.

Privacy and enquiry data · What to include