MACHS

Moulded grating

50 × 50 × 50 mm moulded grating

50 mm-deep moulded FRP grating with 50 × 50 mm mesh for platform selection. Review the sample load conditions, then send your span, loads and panel sizes for configuration review.

MACHS supplied moulded grating representative product-family photograph
Representative moulded grating photograph from the MACHS supplied archive. Confirm the exact geometry, dimensions, resin and surface against the approved order drawing; the photograph is not evidence of the tested configuration.
← Moulded grating

Specification notes

Mesh50 × 50 mm
Depth50 mm
Load evidenceSample opening 350 mm; do not transfer to other spans

Parameter source: P01 → N033 / V9 2026-11-05 / V8 R3. Only the listed configuration is described. Missing dimensions, mass and working loads are not estimated.

Confirm the opening and access requirements

This entry is 50 × 50 mm mesh and 50 mm depth. Check the actual clear opening, intended traffic and any dropped-object or public-access requirements before choosing a larger mesh.

Keep load tests with their support conditions

The historical load-reference sample uses a 350 mm opening. The later customer-headed EN 124 references have their own sample and support conditions. Neither should be converted into a working-load table for a different span or a universal loading class.

Check the scope before placing an order

Give the panel size, resin, surface, support layout, loading and destination. Customer-headed evidence is identified in the technical pack and the original is held for release review; it is not presented as a MACHS-held product certificate.

Define mesh, opening and depth separately

Use the mesh designation and panel depth as separate dimensions. Mesh pitch and the clear gap between ribs are different measurements; a smaller secondary mesh is another configuration detail. Specify the walking surface and resin independently. Ask for the applicable section drawing before matching a photograph or an abbreviated size to an order.

Decide what the application needs

For walkways, trench covers and platform areas, first identify who or what will cross the panel, support positions, clear span, load contact area and the required deflection limit. Consider drainage, debris, cleaning access and footwear when choosing an opening. A small opening or gritted surface does not by itself demonstrate compliance with a pedestrian-access or slip standard.

Agree the finished panel and fixing scope

List full-panel sizes or each cut part, finished dimensions and units, edge and cut-out locations, identification marks and fixing requirements. Distinguish panel-to-panel joining from attachment to the supporting structure. Agree which drawings, inspection criteria and records accompany the order; do not infer a tested assembly from the panel name alone.

Why the 50 mm panel needs its own drawing

The supplied English catalogue shows more than one rib configuration for the 50 × 50 mm mesh and 50 mm depth family. Do not merge those variants or their weights and loads. The linked load evidence is tied to its sample and support opening; it is not a declaration of a load class for every 50 mm panel.

Swipe or scroll the table horizontally to read all columns on a small screen.

Recorded specification — 50 × 50 × 50 mm moulded grating
Specification itemRecorded value
Mesh50 × 50 mm
Depth50 mm
Load evidenceSample opening 350 mm; do not transfer to other spans
Does a mesh size identify the whole specification?

No. Confirm mesh pitch, clear opening, depth, rib geometry, resin, surface, panel outline and supports. The same nominal mesh and depth can have different rib sections or formulations.

Technical pack for this configuration

Use the model, drawing revision and tested conditions together. Missing files are not evidence of a verified specification.

SHIN2009059850CM

50 × 50 × 50 mm; opening 350 mm

Do not substitute for a different opening or span.

Applicant / publisher: As recorded in original report · Source: Document reference

Version: As issued; see original · Sample record — applicability review required

Reference / method: Conditional load test · Issued: 2020-09-27

Test report: no expiry inferred. Confirm original and order applicability before use.

Original is held for release / applicability review.

260717017SHF-003

50×50;50mm;1220×1220mm;申请人声明A15

CUSTOMER-HEADED REFERENCE: applicant FG Structures Ltd. Not a MACHS-held certificate. Original release requires review. Only the identified tested specimen/configuration. Matching nominal dimensions does not establish the same resin, formulation, surface, batch or working load. Confirm the proposed supply against the complete original report.

Applicant / publisher: FG Structures Ltd · Source: Customer-headed reference — not a MACHS-held certificate

Version: As issued; see original · Customer-headed latest located revision; applicability limited to tested sample

Reference / method: EN 124-1:2015 / EN 124-5:2015 · Issued: 2026-08-20

No blanket current certification or working-load claim. Client-headed original is controlled.

Original is held for release / applicability review.

260702008SHF-001-R2

50×50;50mm

CUSTOMER-HEADED REFERENCE: applicant FG Structures Ltd. Not a MACHS-held certificate. Original release requires review. Only the identified tested specimen/configuration. Matching nominal dimensions does not establish the same resin, formulation, surface, batch or working load. Confirm the proposed supply against the complete original report.

Applicant / publisher: FG Structures Ltd · Source: Customer-headed reference — not a MACHS-held certificate

Version: R2 · Customer-headed latest located revision; applicability limited to tested sample

Reference / method: EN 13501-1:2018;EN ISO 9239-1:2025;EN ISO 11925-2:2026 · Issued: 2026-07-10;修订2026-07-24

No blanket current certification or working-load claim. Client-headed original is controlled.

Original is held for release / applicability review.

Drawing candidate: identity confirmed; order and report applicability NOT confirmed.

50X50S50 格栅图纸 · 7034c456

3007 ± 3 × 1007 ± 3 mm panel; 50 mm pitch; 50 ± 1 mm depth

Confirmed: the drawing title, printed A0 revision and the dimensions stated above. Not confirmed: current ordered configuration or correspondence to the tested specimen. Two different panel layouts share A0. Neither is established as the 1230×450×50 mm CO350 test component, its support assembly or a current released order drawing. Neither panel drawing identifies the 1230 × 450 × 50 mm / CO350 tested component; do not infer load or A15 applicability.

Applicant / publisher: Nantong Machs Composite Material Co., Ltd. (as printed) · Source: Document reference

Version: A0 (printed; no approved issue date recorded) · Parallel candidate — not an approved successor

Reference / method: Drawing reference — not a test report · Issued: See original

Two different panel layouts share A0. Neither is established as the 1230×450×50 mm CO350 test component, its support assembly or a current released order drawing. Neither panel drawing identifies the 1230 × 450 × 50 mm / CO350 tested component; do not infer load or A15 applicability.

Original is held for release / applicability review.

Drawing candidate: identity confirmed; order and report applicability NOT confirmed.

50X50S50 格栅图纸 · e6ac0522

1007 ± 3 × 1007 ± 3 mm panel; 50 mm pitch; 50 ± 1 mm depth

Confirmed: the drawing title, printed A0 revision and the dimensions stated above. Not confirmed: current ordered configuration or correspondence to the tested specimen. Two different panel layouts share A0. Neither is established as the 1230×450×50 mm CO350 test component, its support assembly or a current released order drawing. Neither panel drawing identifies the 1230 × 450 × 50 mm / CO350 tested component; do not infer load or A15 applicability.

Applicant / publisher: Nantong Machs Composite Material Co., Ltd. (as printed) · Source: Document reference

Version: A0 (printed; no approved issue date recorded) · Parallel candidate — not an approved successor

Reference / method: Drawing reference — not a test report · Issued: See original

Two different panel layouts share A0. Neither is established as the 1230×450×50 mm CO350 test component, its support assembly or a current released order drawing. Neither panel drawing identifies the 1230 × 450 × 50 mm / CO350 tested component; do not infer load or A15 applicability.

Original is held for release / applicability review.

Installation planning checklistRequest missing or applicable files

Compare this configuration

Installation planning · Your buying path · Technical resources

Applications

Coordinate grating, framing, rails and connections.Plan industrial platforms and equipment accessCoordinate the component list, support and connection details, maintenance openings and responsibility for installation.

Technical resources

Section drawings, report relationships and unresolved geometryCheck catalogue section identity, held drawing candidates and the exact information still required before order or evidence release.

Selection guides

MACHS pultruded FRP grating panels in the workshop; representative family photograph, not a tested specimen identificationChoose resin from the actual exposureSend chemical concentration, temperature and contact conditions before asking which resin is suitable.MACHS pultruded FRP grating panels in the workshop; representative family photograph, not a tested specimen identificationCompare grating quotations on the same basisAlign the configuration, finished quantities and delivery scope before comparing the total price.MACHS pultruded FRP grating panels in the workshop; representative family photograph, not a tested specimen identificationRead a load table with its support conditionsMatch the panel, support arrangement, span and loading before using a load value.

Related products in this family

Review the section, dimensions and evidence for each entry. A related product is not an interchangeable or approved substitute.

Green micro-mesh grating photograph from the supplied MACHS archive13/40 mm mesh, 30 mm moulded grating30 mm moulded FRP grating with 13/40 mm mesh for walkway selection. Check the recorded surface and sample-specific slip report, then send your application and panel requirements.MACHS supplied moulded grating representative product-family photograph38 × 38 × 38 mm moulded grating38 mm-deep moulded FRP grating with 38 × 38 mm mesh for walkway and platform selection. Compare resin and surface options, then send panel sizes and support conditions for quotation.MACHS supplied moulded grating representative product-family photographH30 moulded mini-mesh grating30 mm moulded mini-mesh FRP grating for walkway and platform selection. Check the recorded mesh and surface options, then send panel sizes, service conditions and quantities for review.

Request specifications

Selected product: 50 × 50 × 50 mm moulded grating. This configuration is included with your enquiry.

State known conditions and write "not sure — please advise" for anything unresolved. No need to guess the resin or load.

Privacy and enquiry data · What to include

Attach your drawing or specification and include its drawing number and revision in the requirements. You can also contact info@machsfrp.com.